[ Location ][ General Construction ][ Ground Formations ][ Well Finishing ] Location The well casing should terminate above ground and the ground surface at the well site should be built up when necessary so that surface water will drain away from the well in all directions. A well should be located so it will be accessible for pump repair, cleaning, treatment, testing and inspection. The top of the well should not be within a basement nor under a building with no basement. When adjacent to a building, the well should be at least five feet outside any projection, such as overhanging eaves.
The real determination of potability of water must be based on bacteriological tests, not on arbitrary distances. The following distances, however, can be used as a guide - providing subsurface materials have the natural filtering capability of sand:
Where the earth formations near the ground surface consist of coarse gravel, limestone or disintegrated rock, distances on the order of those just given do not apply. Greater distances are needed. Distance cannot be relied upon where surface materials such as these permit rapid percolation of water with little chance for natural purification.
| |||||||||||||||||||||